CAD模型選擇
{eaton_cad/19010/19042/19146/19481.prj},{NB=118700},{PLID=118700},{NETTO_WEIGHT=0.16500},{EF000346=5.16},{EF003344=2},{EF003345=0},{EF003346=0},{EF003347=0},{EF003348=1},{EF003349=0},{EF003350=0},{EF003351=0},{EF006706=4},{EF007498=0},{EF009889=3},{EF000008=22.5},{EF000040=99},{EF000049=114.5},{CUSTOMS_TARIFF_NUMBER1=85364900},{PREVIEW=../../../_pool_/10/8a/ce/19481_preview_40.png},{MANUTYPEDESC=ESR5-NO-21-24VAC-DC},{DESCSHORT=Safety relay emergency stop/protective door, 24VDC/AC, 2 enabling paths}
請根據技術需求選擇所需產品. 可選屬性在表格中高亮顯示. 選擇可以通過點擊表格或數值來重置.
118700
HELP_VARIABLE
Company
Eaton's CAD
Description
Device for monitoring of safety-related circuits [EC001449]
Bill of material
118700
PREVIEW
Preview
PLID
118700
118700
MANUTYPEDESC
Manufacturer Type Description
ESR5-NO-21-24VAC-DC
ESR5-NO-21-24VAC-DC
DESCSHORT
Short Description
Safety relay emergency stop/protective door, 24VDC/AC, 2 enabling paths
Safety relay emergency stop/protective door, 24VDC/AC, 2 enabling paths
DESCLONG
Long Description
Safety relay dual-channel, for implementing the basic functions emergency switching off, emergency stop, and protective door, supply voltage 24VDC or 24VAC 50/60Hz, 2 Enable current paths (IEC/EN 60204 Stop category 0), 1 signal current path, busbar tag shroud to EN 50274 with vertical actuation from the front finger- and back-of-hand proof, suitable for cat. 4 according to EN 954-1 / PL e according to EN ISO 13849-1 / SILCL 3 according to IEC 62061 / SIL 3 according to IEC 61508, degree of protection IP20, installation location IP54 minimum, TÜV tested, rated impulse voltage 6 kV / safe isolation, reinforced insulation
Safety relay dual-channel, for implementing the basic functions emergency switching off, emergency stop, and protective door, supply voltage 24VDC or 24VAC 50/60Hz, 2 Enable current paths (IEC/EN 60204 Stop category 0), 1 signal current path, busbar tag shroud to EN 50274 with vertical actuation from the front finger- and back-of-hand proof, suitable for cat. 4 according to EN 954-1 / PL e according to EN ISO 13849-1 / SILCL 3 according to IEC 62061 / SIL 3 according to IEC 61508, degree of protection IP20, installation location IP54 minimum, TÜV tested, rated impulse voltage 6 kV / safe isolation, reinforced insulation
INTNO
International product number
4015081168408
4015081168408
NETTO_WEIGHT
Netto weight
0.16500
0.16500
kg
ECLASS_13_0
Device for monitoring of safety-related circuits [ACO304016]
ETIM_9_0
Device for monitoring of safety-related circuits [EC001449]
EF000010
Model
Basic device
Basic device
EF003972
Rail mounting possible
true
EF003340
With detachable clamps
true
EF003961
Type of electric connection
Screw connection
EF002991
Voltage type (supply voltage)
AC/DC
AC/DC
EF007532
Supply voltage AC 50 Hz
24 - 24
24 - 24
V
EF007533
Supply voltage AC 60 Hz
24 - 24
24 - 24
V
EF007534
Supply voltage DC
24 - 24
24 - 24
V
EF007270
Suitable for monitoring of position switches
true
true
EF007268
Suitable for monitoring of emergency-stop circuits
true
EF007272
Suitable for monitoring of valves
false
EF007269
Suitable for monitoring of optoelectronic protection equipment
false
false
EF007271
Suitable for monitoring of tactile sensors
false
EF007266
Suitable for monitoring of magnetic switches
false
false
EF007267
Suitable for monitoring of proximity switches
false
EF008245
Evaluation inputs
1-channel
1-channel
EF000346
Power consumption
5.16
5.16
W
EF003342
With start input
true
true
EF004057
With muting function
false
EF003343
With feedback circuit
true
EF001129
Release-delay
0 - 0
0 - 0
s
EF002954
Type of control voltage 1
AC/DC
AC/DC
EF002952
Control voltage 1
24 - 24
24 - 24
V
EF002955
Type of control voltage 2
AC/DC
AC/DC
EF002953
Control voltage 2
24 - 24
24 - 24
V
EF003344
Number of outputs, safety related, undelayed, with contact
2
2
EF003345
Number of outputs, safety related, delayed, with contact
0
0
EF003346
Number of outputs, safety related, undelayed, semiconductors
0
EF003347
Number of outputs, safety related, delayed, semiconductors
0
EF003348
Number of outputs, signalling function, undelayed, with contact
1
1
EF003349
Number of outputs, signalling function, delayed, with contact
0
0
EF003350
Number of outputs, signalling function, undelayed, semiconductors
0
EF003351
Number of outputs, signalling function, delayed, semiconductors
0
EF005294
Voltage type (operating voltage)
AC/DC
AC/DC
EF008206
Operating voltage AC 50 Hz
24 - 24
24 - 24
V
EF008207
Operating voltage AC 60 Hz
24 - 24
24 - 24
V
EF008208
Operating voltage DC
24 - 24
24 - 24
V
EF006706
Rated switch current
4
4
A
EF004105
Type of safety according to IEC 61496-1
None
EF007498
Stop category according to IEC 60204
0
0
EF007399
Performance level according to EN ISO 13849-1
Level e
Level e
EF009889
SIL according to IEC 61508
3
EF004145
With approval for BG BIA
false
EF001783
With approval according to UL
true
EF000008
Width
22.5
22.5
mm
EF000040
Height
99
99
mm
EF000049
Depth
114.5
mm
EFDE0031
With approval for TÜV
true
true
DATA_SHEET
Data sheet
Data sheet
Previews
3D
2D
下載CAD模型
生成CAD模型
生成PDF資料表
添加到購物籃
Embedded user actions